LavaLAMP™ DNA Component Kit

Fast, Sensitive DNA LAMP Assays in a Fully Optimizable Kit Format

  • Loop-mediated Isothermal Amplification (LAMP): Allows researchers to run assays outside of high-tech laboratories using low complexity instrumentation
     
  • 68-74°C Reaction Temperature: Reduces background amplification and improves primer specificity depending on the target
     
  • Lyophilization-ready: Component formulations enable generation of room temperature stable test kits through lyophilization
     
  • Custom/Bulk Available: Custom volumes and dispensing available to match your specific requirements
     
  • Matched Performance to LavaLAMP™ DNA Master Mix: Assists current users of the master mix product by streamlining additional assay optimization with this kit.
 Read Full Product Description

The LavaLAMP™ DNA Component Kit is designed for loop-mediated isothermal amplification (LAMP) assay development. This kit contains a unique, highly processive DNA polymerase enzyme with strong strand displacement activity, making it well suited to LAMP and other isothermal amplification assays.

The enzyme in this kit is identical to the enzyme present in the LavaLAMP™ DNA Master Mix, but the individual reagent format of this kit, as opposed to the master mix format, gives you complete control of each LAMP assay and full optimization capabilities. Importantly, this kit is an exact deconstruction of the LavaLAMP® DNA Master Mix, and when reactions are setup using the initial Experimental reaction conditions outlined in the Component Kit User Manual, the composition of that reaction formulation matches the composition of the Master Mix-based reaction.

To aid in assay development and future lyophilization of LavaLAMP®-based reactions, all components in this kit are compatible with lyophilization. This feature means that reactions will not have to be reformulated or reoptimized to remove components that hinder lyophilization such as glycerol and betaine.

For more information on loop-mediated isothermal amplification, please look at the following recorded webinar, “Loop-Mediated Isothermal Amplification (LAMP): Assay Development Challenges and Solutions.”


Equivalent Performance Between the LavaLAMP™ DNA Master Mix and DNA Component Kit

Equivalent Performance Between the LavaLAMP™ DNA Master Mix and DNA Component Kit

Figure 1. Performance comparison of the LavaLAMP™ DNA Component Kit and the LavaLAMP™ DNA Master Mix. LAMP reactions (8 replicates per test) were set up using the indicated kits and targets with the same concentrations of Target-Specific Primer Mixes (1X) and the same target input amounts. The LavaLAMP DNA Component Kit reactions were formulated to 1X LavaLAMP DNA Buffer, 10 mM MgSO4 and 0.8mM dNTPs (each) to match the final formulations of the LavaLAMP DNA Master Mix reactions. Green Fluorescent Dye was included in all reactions. Reactions were run on a CFX96 Thermal Cycler (Bio-Rad) at the following temperatures - M13mp18, 74°C and tcdA, 69°C and fluorescence was measured during the course of the 60-minute reactions to determine TTR. NTC = No Target Control.


Faster, More Sensitive Detection with LavaLAMP™ DNA Component Kit

Faster, More Sensitive Detection with LavaLAMP™ DNA Component Kit

Figure 2. Performance comparison of the LavaLAMP™ DNA Component Kit vs. Competitor Kits. LAMP reactions were set up using the indicated kits according to manufacturer’s recommendations. Target DNA (C. difficile) at varying input amounts, tcdA target LAMP primers, and Green Fluorescent Dye (LavaLAMP Kit) were included in all reactions. Reactions were run on a CFX96 Thermal Cycler (Bio-Rad) at the following temperatures: LavaLAMP; 69°C; other kits at the recommended 65°C and fluorescence was measured over 60 minutes to determine the TTR. NTC = No Target Control.


Consistent Performance Between Multiple Operators

Consistent Performance Between Multiple Operators

Figure 3. Analysis of operator to operator consistency. On the same day, six replicate LAMP reactions were set up per condition per by three different operators using the indicated amounts of target DNA M13mp18,  M13mp18 target LAMP primers, and Green Fluorescent Dye. Reactions were run on a CFX96 Thermal Cycler (Bio-Rad) at 74°C and amplification was monitored in real-time. Results were analyzed to determine the TTR and averaged. NTC = No Target Control.


Consistent Day to Day Performance

Consistent Day to Day Performance

Figure 4. Analysis of day to day assay consistency. On three different days, six replicate LAMP reactions were set up per condition using the indicated amounts of target DNA M13mp18, M13mp18 target LAMP primers, and Green Fluorescent Dye. On each day the reactions were run on a CFX96 Thermal Cycler (Bio-Rad), amplification was monitored in real-time, and then results were analyzed to determine the TTR. Replicates were averaged and presented. NTC = No Target Control.


Optimization of Primer Set Design and Reaction Temperature are Critical to Developing Fast, Low Background LAMP Assays

Optimization of Primer Set Design and Reaction Temperature are Critical to Developing Fast, Low Background LAMP Assays

Figure 5. Assessing the importance of primer design and reaction temperature on LAMP assay performance. Three primer sets targeting M13mp18 were designed using the LAMP Designer software (Premier Soft) and screened across a temperature range of 68°C – 74°C using the LavaLAMP™ DNA Component Kit at the recommended 1X, default reaction conditions. Duplicate assays were run for each test, and real-time detection was performed on a CFX96 Thermal Cycler (Bio-Rad) using Green Fluorescent Dye. NTC = No Target Control. Primer Set 3 provided the fastest positive Time to Result with the least amount of background (longest TTR for NTC reactions). Within Primer Set 3, 74°C provided the best resolution between the positive and negative samples.

Note: Exact temperatures were set by the CFX96 Thermal Cycler instrument software when the range was selected. Specific temperatures tested will depend on the real-time instrument used.

Contact your local distributor for pricing
Product Description Size Cat. No.
LavaLAMP™ DNA Component Kit   500 rxn 30076-1
LavaLAMP™ DNA Component Kit with Dye   500 rxn 30077-1
Green Fluorescent Dye   500 rxn 30078-1

 

ORDER INFORMATION
Both LavaLAMP™ DNA Component Kits contain: 10X LavaLAMP™ DNA Buffer, LavaLAMP™ DNA Enzyme, Magnesium Sulfate, 100 mM, DNA Positive Control LAMP Primer Mix and DNA Positive Control. The LavaLAMP™ DNA Component Kit with Dye also contains Green Fluorescent Dye for fluorescent detection of amplified DNA. The Green Fluorescent Dye is also available separately.

Licensing information: Lucigen is a fully licensed provider of LAMP reagents for research use. Patents WO 00/28082, WO 01/34790, and WO 01/77317 regarding the LAMP method are owned by the Eiken Chemical Co. Ltd. LavaLAMP™, OmniAmp® and Bst Polymerase, Exonuclease minus are sold by Lucigen under license for use in LAMP for research use only. The products may not be used for LAMP-based human or diagnostic purposes without obtaining a license from Eiken. US Patent 8093030 for LavaLAMP and OmniAmp is owned by Lucigen Corp.

It is the sole responsibility of the buyer to ensure that use of the product does not infringe the patent rights of third parties. If the purchaser is not willing to accept these use limitations, Lucigen Corporation is willing to accept return of the product for a full refund.