产品描述

The Ribo-Zero™ rRNA Removal Kit (Human/Mouse/Rat) Low Input is ideal for removing rRNA from formalin-fixed paraffin-embedded (FFPE) RNA samples as well as from intact and partially degraded human, mouse, and rat total RNA preparations.

Benefits

  • Removes >98% of 28S, 18S and 5.8S rRNA, and up to 95% of 5S rRNA from intact and partially degraded human, mouse, and rat total RNA preparations including RNA isolated from FFPE samples.
  • Single-pass process yields RNA sufficiently depleted of rRNA for RNA-Seq, poly(A) tailing, random-primed cDNA synthesis, and other applications.
  • Recovers the 5´- and 3´-end fragments of mRNAs, as well as other non-rRNAs, in an intact, partially degraded, or FFPE sample.
  • Uses 100 ng to 1 µg of total RNA.

 

  1. Prepare Ribo-Zero™ Microspheres (15 minutes).
  2. Treat 100 ng to 1 µg total RNA with Ribo-Zero™ rRNA Removal Solution (25 minutes).
  3. Treat sample with and remove Ribo-Zero™ Microspheres (20 minutes).
  4. Purify the rRNA-depleted samples by ethanol precipitation (90 minutes) or column method (provided by the user; 15 minutes).
Figure 1. Overview of the Ribo-Zero™ rRNA Removal Kit (Human/Mouse/Rat) Low Input process.

Figure 1 Figure 2. Agilent Bioanalyzer analysis of Universal Human Reference RNA (UHRR) before and after treatment with the Ribo-Zero rRNA Removal Kit (Human/ Mouse/Rat) Low Input. A 200-ng aliquot of UHRR (Stratagene) was treated with the RiboZero Low Input Kit. A mock-treated sample was prepared from 200 ng of total RNA without the addition of the Ribo-Zero rRNA Removal Solution. After purification, the mock-treated sample was diluted fourfold. Both rRNA-depleted (red) and mock-treated (blue) RNA were analyzed using the Agilent RNA 6000 Pico Kit. Figure 2 Figure 3. Agilent Bioanalyzer analysis of rRNA removal from FFPE RNA. FFPE RNA samples (500 ng) were analyzed using the Agilent RNA 6000 Pico chip before (blue) and after (red) treatment with the Ribo-Zero rRNA Removal Kit (Human/Mouse/Rat) Low Input.